Hunter Street Student Residence

North Vancouver, BC

High-Rise Energy Modeling Sustainability Package Step 3 + EL3
TEDI
0 kWh/m²/yr
LCA intensity (A-C)
0 kg CO2e/m²
Floors / suites
0 / 0

Project Overview

Twenty-four-storey student residence (≈654 suites) in the District of North Vancouver. Our rezoning mandate covered the complete Climate-Ready Rezoning Policy (CRRP) package alongside Step 3 + EL3 compliance: a rezoning (DP) energy model, a Comprehensive Energy Efficiency & Sustainability Report (CEESR) containing the Whole-Building LCA (A-C), Refrigerant LCE, CEEP strategy, BCBC Step Code report, OCP Energy Compliance, OCP Water Conservation plan, and OCP GHG Reduction plan, plus OCP Schedule B narratives and forms.

Key technical challenges included managing cooling loads and ventilation for small high-density suites, and right-sizing equipment while maintaining resilience. We coordinated MERV-13 filtration and active-cooling commitments, and set façade infiltration at ≈0.2 L/s·m² to reflect best-practice air-barrier targets. The preferred system is central air-to-water heat pumps with hydronic fan coils, high-efficiency ERVs, and heat-pump DHW pre-heat with boiler support for extreme cold.

Outcomes at DP demonstrate Step 3 + EL3: TEUI ≈ 80.28 kWh/m²/yr, TEDI ≈ 28.64 kWh/m²/yr, and GHGI ≈ 2.9 kg CO2e/m²/yr. Embodied carbon (A-C) intensity is ≈ 300 kg CO2e/m², and refrigerant LCE totals ≈ 37.70 kg CO2e/m². The submission included the CEESR package, the Step Code Part 3 Energy Checklist, CRRP commitment documents, and Design Verification (DNV) energy inputs for the CRP.

Hunter Street massing
Systems schematic

Project Data

Building TypeHigh-rise student residence (Part 3)
StageRezoning (DP) / Building Permit
AddressHunter Street, District of North Vancouver
Floors / Units24 storeys, ≈654 suites; GFA ≈ 17,013 m²
ComplianceBCBC 2024 Step 3 + EL3; CRRP (rezoning)
Targets (DP)TEUI =120; TEDI =30; GHGI =3.0 kg CO2e/m²/yr
EnvelopeWalls: steel stud w/ R14 + 4" exterior insulation; roof R-30; floor over parkade R-20
MechanicalATW heat pumps + fan coils; gas boiler support; corridor HP MUA (gas backup); ERVs ≈80% SRE; HP DHW pre-heat (≈25%)
Software / WeatherIES-VE / Vancouver_BC_CWEC

Our Contribution

  • Rezoning energy model (DP) IES-VE 2023; Step 3 + EL3; corridor credits; NECB/CoV guideline alignment.
  • Comprehensive Energy Efficiency & Sustainability Report WB LCA (A-C); Refrigerant LCE; CEEP strategy; BCBC Step Code report; OCP Energy Compliance; OCP Water Conservation plan; OCP GHG Reduction plan.
  • CRRP submissions MERV-13 filtration commitment and active-cooling commitment documents.
  • Design Verification (DNV) support CRP Design Verification Form energy data and summaries.
  • Step Code Part 3 Energy Checklist Complete energy-related sections for DP.
  • Envelope & systems parametrics WWR/SHGC, spandrel strategy, infiltration targets, ERV sizing, ATW HP + boiler staging.
  • End-use analytics Annual electricity and end-use shares for capacity/right-sizing.

Key Results

TEUI80.28 kWh/m²/yrDevelopment Permit model
TEDI28.64 kWh/m²/yrArea-weighted
GHG intensity2.9 kg CO2e/m²/yrLow-carbon systems
Embodied emissions intensity300 kg CO2e/m²LCA A-C; total 5,089,960 kg
Refrigerant emissions intensity37.70 kg CO2e/m²Life-cycle equivalent (A-C): 641,435 kg CO2e
Annual electricity1,340,652 kWhModeled end-use total
Annual gas195,415 kWhModeled end-use total
ComplianceBCBC Step 3 + EL3 (DP)CRRP package submitted

Need modeling for high-rise student housing?

We deliver code-aligned analysis and documentation for faster permits.