Keefer Street

Vancouver, BC

10-Storey Mixed-Use VBBL ZEBP Whole-Building LCA
GFA (total)
0
GHG emissions intensity (A–C)
0 kg CO2e/m²
Structure
Concrete + Steel

Project Overview

A 10-storey mixed-use development with commercial at grade and residential above, supported by a hybrid concrete and steel structural system over one underground level.

Eleman completed a whole-building Life Cycle Assessment using Athena 5.4 to demonstrate compliance with VBBL 2019 Section 10.4 (ZEBP) at Building Permit, providing material take-offs coordination and permit-ready submission tables.

Keefer rendering
Keefer streetscape

Project Data

LocationChinatown, Vancouver, BC
Building TypePart 3 Mixed-Use
Height10 storeys
GFA (total / LCA)2,882 m² / 2,602 m²
StructureConcrete & steel wall frame
StageBuilding Permit
ComplianceVBBL 2019 Sec. 10.4 (ZEBP)
LCA ToolAthena Impact Estimator 5.4

Our Contribution

  • Whole-building LCA Material take-offs coordination and Athena modeling.
  • Permit documentation CoV Embodied Carbon Design Report tables.
  • Compliance review VBBL Sec. 10.4 alignment and narrative.

Key Results

Embodied emissions intensity (A–C)374 kg CO2e/m²Benchmark 400 kg CO2e/m² – compliant
A1–A3 (Product)768,000 kg CO2eRaw materials, manufacturing
A4–A5 (Construction)117,000 kg CO2eTransport and installation
B2/B4/B6 (Use)17,300 kg CO2eMaintenance, replacement, refurbishment
C1–C4 (End-of-life)73,600 kg CO2eDeconstruction, processing, disposal
Total A–C973,309 kg CO2eEquivalent life-cycle embodied emissions
Total A–D1,720,000 kg CO2eIncluding Module D (beyond building life)

Need VBBL ZEBP embodied carbon support?

We prepare clear, permit-ready LCA documentation aligned to Section 10.4.

Book a consultation